MOTOROLA, INC. FT100 M Card Type T1 CSU/DSU, Ethernet Chip Set Unidentified I/O Options Monitor ports, alarm port Network Transfer Rate 10Mbps Topology Star Wiring Type Unshielded twisted pair Transfer Rate 1.544Mbps Data Bus Serial Protocol AMI, B8ZS Frame Type SF, ESF [Image] CONNECTIONS Function Label Function Label Monitor receive CN1 Serial control port CN6 Monitor transmit CN2 DSX-1, RS-232, RS-449, CN7 RS-530, or V.35 serial data port 2 (on daughterboard) T1 interface CN3 DC power in CN8 UTP connector CN4 Alarm port (see pinout SC1 below) DSX-1, RS-232, RS-449, CN5 RS-530, or V.35 serial data port 1 (on daughterboard) Note:Standard serial ports are provided on included adapter cables. SC1 PINOUT Function Pin Function Pin Normally closed connection 1 Signal common 3 Normally open connection 2 Not used 4 USER CONFIGURABLE SETTINGS Setting Label Position » Signal ground connected to chassis E1 Pins 2 & 3 closed ground Signal ground not connected to E1 Pins 1 & 2 closed chassis ground » Factory configured - do not alter S1/1 Unidentified » Factory configured - do not alter S1/2 Unidentified » Factory configured - do not alter S1/3 Unidentified » Factory configured - do not alter S1/4 Unidentified » Factory configured - do not alter S1/5 Unidentified » Factory configured - do not alter S1/6 Unidentified » Factory configured - do not alter S1/7 Unidentified » Factory configured - do not alter S1/8 Unidentified » Factory configured - do not alter S2/1 Unidentified » Factory configured - do not alter S2/2 Unidentified » Factory configured - do not alter S2/3 Unidentified » Factory configured - do not alter S2/4 Unidentified » Factory configured - do not alter S2/5 Unidentified » Factory configured - do not alter S2/6 Unidentified » Factory configured - do not alter S2/7 Unidentified » Factory configured - do not alter S2/8 Unidentified » Factory configured - do not alter S28/1 On » Factory configured - do not alter S28/2 On » Factory configured - do not alter S28/3 On » Factory configured - do not alter S28/4 On » Factory configured - do not alter S28/5 On » Factory configured - do not alter S28/6 On » Factory configured - do not alter S28/7 On » Factory configured - do not alter S28/8 Off USER CONFIGURABLE SETTINGS (CON’T) Setting Label Position » One stop bit selected S29/5 On Two stop bits selected S29/5 Off » 8 data bits selected S29/6 On 7 data bits selected S29/6 Off CONTROL PORT CONFIGURATION Setting E25 E26 E27 » DCE Pins 1 & 2, 3 & Pins 1 & 2, 3 & Pins 1 & 2, 3 & 4 closed 4 closed 4 closed DTE Pins 1 & 3, 2 & Pins 1 & 3, 2 & Pins 1 & 3, 2 & 4 closed 4 closed 4 closed SERIAL PORT SPEED SELECTION Setting S29/1 S29/2 2400bps Off Off 4800bps Off On 9600bps On Off » 19.2Kbps On On DATA PARITY SELECTION Setting S29/3 S29/4 » Disabled On N/A Even Off On Odd Off Off FLOW CONTROL SELECTION Setting S29/7 S29/8 » Flow control disabled On On XON/XOFF flow control On Off enabled RTS/CTS flow control Off On enabled DIAGNOSTIC LED(S) LED Color Status Condition TXD2 Green On Data is being transmitted to port 2 TXD2 Green Off Data is not being transmitted to port 2 RXD2 Green On Data is being received from port 2 RXD2 Green Off Data is not being received from port 2 TXD1 Green On Data is being transmitted to port 1 TXD1 Green Off Data is not being transmitted to port 1 RXD1 Green On Data is being received from port 1 RXD1 Green Off Data is not being received from port 1 YEL Red On Yellow alarm condition detected YEL Red Off Yellow alarm condition not detected AIS Red On All Ones Signal detected AIS Red Off All Ones Signal not detected DIAGNOSTIC LED(S) (CON’T) LED Color Status Condition LOS Red On Loss of signal detected LOS Red Off Loss of signal not detected SYN Green On Valid framing pattern received from T1 interface SYN Green Off Valid framing pattern not received from T1 interface PWR Green On Power is on PWR Green Off Power is off USER CONFIGURABLE SETTINGS Setting Label Position » Factory configured - do not alter SW1 Off » Factory configured - do not alter SW2 Off » Factory configured - do not alter SW3 On » Factory configured - do not alter SW4 On » Factory configured - do not alter SW5 Off » Factory configured - do not alter SW6 On » Factory configured - do not alter SW7 Off » Factory configured - do not alter SW8 Off MISCELLANEOUS TECHNICAL NOTES Diagram not available. FT100 M (RS-449/530 INTERFACE) MISCELLANEOUS TECHNICAL NOTES Diagram not available. The card's jumper(s) must be set for Test Mode operation.